PO-500 type
View favorites See the comparison
Prevents water from breaking (breaking) due to natural evaporation of floor drain traps in public toilets, machine rooms, resort apartments, etc., where almost no water flows in.
Since the trap is automatically replenished with a constant flow rate of water, it prevents the foul odor from the drain pipe from flowing back into the building.
Where to use
Public toiletmachine room

Major features

  • Detects the pressure drop in the water supply pipe and automatically replenishes water.
  • Since it has a built-in check valve, there is no need to install a separate check valve.

specification

Product code PO-500
Valve type Trap primer valve
Nominal diameter 15 (1/2)
End connection Inlet: NPT 1/2 screw Outlet: NPT 1/2 union screw
Working pressure range 0.25-0.52MPa
Applicable temperature 5-43 ℃
Allowable impact pressure 1.0MPa
Mounting posture Vertical mounting with threads facing up

Download materials

Download materials

Common to all product symbols

PO-500 Catalog

PO-500 price list

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.