MD-14W type
View favorites See the comparison
It is a self-powered adjustment valve that releases an excessive amount of pressure due to load fluctuations and keeps the pressure of equipment and piping constant. It is a kind of high-performance relief valve. For example, in the case of continuous operation of the pump, the discharge side pressure changes due to load fluctuation, but the discharge pressure is adjusted to be constant by providing an MD-14 type primary pressure adjustment valve in the bypass circuit and releasing excessive pressure. can. It can also be used as a relief valve for pressure tanks and pipes.
Where to use
Pump reliefPressure tank / piping

Major features

  • Used as a pump relief valve. The operation is stable with a structure that considers hunting and vibration.
  • It can be used as a relief valve for pressure tanks and piping.
  • Since the piston type balance structure is adopted, the change in blowout pressure due to back pressure fluctuation is small.
  • Maintenance is easy because the internal inspection can be performed by disassembling from one direction on the upper side.
  • MD-14CN type is a rust-resistant nylon coating.

specification

Product code MD14W-B □The symbol of the set pressure adjustment range is entered in □.
Valve type Primary pressure control valve
type Goods
Nominal diameter 15-150 (1/2-6)
Applicable fluid Water / airWhen used in a dry air pneumatic system with an oil-free compressor (turbo compressor or positive displacement compressor (rotary oil-free type)), rubber parts may deteriorate significantly in a short time (ozone cracks occur). Please contact us if you would like to install it in such a place.When using it for a water supply device, please use the MD-14CN type, which conforms to the performance standards of the Waterworks Law.
Fluid temperature 5-60 ℃
Set pressure adjustment range Nominal diameter 80 or less L: 0.05 to 0.35MPa, M (MD-14CN type is H): 0.3 to 0.7MPa
Nominal diameter 100 or more L: 0.05 to 0.35 MPa, M (MD-14CN type is H): 0.3 to 0.5 MPaMD-14W, 14H type also manufactures set pressure adjustment range: nominal diameter 80 or less: 0.65 to 1.0MPa, nominal diameter 100 or more: 0.45 to 0.8MPa.
Fluid viscosity
End connection JIS 10K RF flangeWe also manufacture sluice valve flanges for waterworks with a nominal diameter of 100 or more.
Mounting posture Horizontal / vertical freedomWhen installing in vertical piping, keep the nominal diameter up to 80 and allow a large maintenance space. If the nominal diameter is 100 or more, install it upright on the horizontal pipe.
Material body FCIn the case of fuel oil, gasoline, light oil, etc., the material of the main body may be specified depending on the destination (Ministry of Land, Infrastructure, Transport and Tourism, Ministry of Defense, etc.), so please check.
Material parts CAC406, SUS
Material Diaphragm disc NBR
Painting or coating coating Inner surface: Liquid epoxy resin for water supply
Exterior: Metallic blue
  • For MD-14W and 14H types, we also manufacture a pressure gauge with a connection hole (JIS Rc 1/4 screw) on the side of the main body, or a pressure gauge with a pressure gauge attached to it. (The maximum scale of the pressure gauge is the set pressure adjustment range L (0.6MPa), M, H (1.6MPa).)

Download materials

Download materials

Common to all product symbols

MD-14W Catalog

MD-14W price list

MD-14W outline drawing

MD-14W Instruction Manual

MD14W-B □

MD14W-B (100-150A) reference drawing

MD14W-B (15-80A) reference drawing

Frequently Asked Questions and Explanations

What is the purpose of the primary pressure control valve installed on the outlet side of the pump?

It is used to prevent overheating due to shutoff operation of the pump and to keep the pump discharge pressure constant.

What is a back pressure valve?

Refers to the primary pressure control valve. A regulating valve that discharges fluid in response to changes in the force on the primary side in order to maintain the fluid pressure on the primary side at a certain constant pressure.

What is the purpose of the water fall prevention valve?

Please check the details.

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.