MD-35F type
View favorites See the comparison
Made of stainless steel, it can be used for various purposes including clean fluids and gases, and has excellent durability. It has a sealed structure that prevents fluid from leaking to the outside.

Major features

  • Adjusting pressure fluctuation is small, and pressure adjustment of large capacity is possible with high accuracy.
  • Uses a pressure balance structure in which pressure fluctuations on the outlet side do not affect the outlet pressure.
  • Maintenance is a disassembly structure from one direction above.
  • The mounting posture is free.
  • The inlet side pressure gauge can be attached directly to the main body.
  • 50% lighter than conventional FC products (compared to our company).

Water Supply Law Performance Standard Certification Registered Product (E-442) Pressure Resistant Leach Durability

specification

Product code MD35F-D □The symbol of the set pressure adjustment range is entered in □. MD35F-D □The symbol of the set pressure adjustment range is entered in □.
Valve type Primary pressure control valve Primary pressure control valve
type Wetting part stainless steel Wetting part stainless steel
Nominal diameter 25-50 (1-2) 65-100 (2 1/2-4)
Applicable fluid Liquid / air that does not corrode water / hot water / oil / materialWhen used in a dry air pneumatic system with an oil-free compressor (turbo compressor or positive displacement compressor (rotary oil-free type)), rubber parts may deteriorate significantly in a short time (ozone cracks occur). ). Please contact us if you want to install it in such a place.・ Inert gas Liquid / air that does not corrode water / hot water / oil / materialWhen used in a dry air pneumatic system with an oil-free compressor (turbo compressor or positive displacement compressor (rotary oil-free type)), rubber parts may deteriorate significantly in a short time (ozone cracks occur). ). Please contact us if you want to install it in such a place.・ Inert gas
Fluid temperature 5 to 90 ° C 5 to 90 ° C
Set pressure adjustment range L: 0.05-0.35MPa
M: 0.3-0.6MPa
H: 0.6-0.8MPa
L: 0.05-0.35MPa
M: 0.3-0.6MPa
Blow-down pressure Set pressure x 10% or less (minimum value 0.02MPa) Set pressure x 10% or less (minimum value 0.02MPa)
Allowable leakage amount None (visual pressure gauge) None (visual pressure gauge)
Minimum differential pressure before and after the valve 0.05MPa 0.05MPa
Fluid viscosity 700cSt or less 700cSt or less
End connection JIS 10K FF flange JIS 10K FF flange
Mounting posture Horizontal / vertical freedomWhen installing in vertical piping, leave a large maintenance space. Horizontal / vertical freedomWhen installing in vertical piping, leave a large maintenance space.
Material body SCS SCS
Material Valve body SUS SUS
Material Valve seat SUS SUS
Material Diaphragm disc NBR NBR
Material Spring case ADC FC
  • We also manufacture a pressure gauge only on the primary side. (The maximum scale of the pressure gauge is the set pressure adjustment range L (0.6MPa), M, H (1.6MPa).)
  • We also manufacture the MD-35FN type, which conforms to the performance standards of the Waterworks Law.

Download materials

Download materials

Common to all product symbols

MD-35F Catalog

MD-35F price list

MD-35F Instruction Manual

MD35F-D □

MD35F-D (25-50A) reference drawing

MD35F-D (65-100A) reference drawing

MD35F-D □

Frequently Asked Questions and Explanations

What is the purpose of the primary pressure control valve installed on the outlet side of the pump?

It is used to prevent overheating due to shutoff operation of the pump and to keep the pump discharge pressure constant.

What is a back pressure valve?

Refers to the primary pressure control valve. A regulating valve that discharges fluid in response to changes in the force on the primary side in order to maintain the fluid pressure on the primary side at a certain constant pressure.

What is the purpose of the water fall prevention valve?

Please check the details.

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.