WVM-02 type
View favorites See the comparison
This is a large-capacity primary pressure control valve that releases an excessive amount of pressure at the desired pressure due to load fluctuations in pipes and circuits such as air conditioning and sanitary equipment, and keeps the pressure on the primary side of the valve constant.
Where to use
Pump reliefPressure tank / piping

Major features

  • Stable operation can be easily obtained by adjusting the sensitivity by adjusting the needle valve opening according to the usage conditions.
  • The basic valve and pilot valve can be easily disassembled for easy maintenance such as adjustment, repair, and parts replacement.
  • The lift limiting mechanism can limit the overflow.

specification

Product code WVM02-B □The symbol of the set pressure adjustment range is entered in □. WVM02-L □The symbol of the set pressure adjustment range is entered in □.
Valve type Primary pressure control valve Primary pressure control valve
Use Goods Goods
Nominal diameter 50-400 (2-16) 40-200 (1 1/2-8)
Applicable fluid Water / hot waterWhen using it for a water supply device, please use WVM-02N type, WVM-02PN type, WVM-02CN type, which are compliant with the performance standards of the Waterworks Law. Water / hot waterWhen using it for a water supply device, please use WVM-02N type, WVM-02PN type, WVM-02CN type, which are compliant with the performance standards of the Waterworks Law.
Fluid temperature 5-60 ℃ 5-60 ℃
Primary side applied pressure 1.0MPa or lessFor nominal diameters of 200 or less, we also manufacture primary side applicable pressure of 1.6MPa or less (JIS 16K RF flange, set pressure adjustment range of 0.5 to 1.6MPa). (If the main body is made of FC, it does not meet the performance standards of the Waterworks Law.) 1.0MPa or lessFor nominal diameters of 200 or less, we also manufacture primary side applicable pressure of 1.6MPa or less (JIS 16K RF flange, set pressure adjustment range of 0.5 to 1.6MPa). (If the main body is made of FC, it does not meet the performance standards of the Waterworks Law.)
Set pressure adjustment range Nominal diameter 200 or less L: 0.05 to 0.35MPa, M: 0.3 to 1.0MPaThe set pressure adjustment range for nominal diameters 40 and 50 is 0.5 to 1.0 MPa, and the product symbols are WVM02-B (main unit FC) and WVM02-L (main unit FCD).
Nominal diameter 250 or more L: 0.05 to 0.35MPa, M: 0.3 to 0.7MPa
Nominal diameter 200 or less L: 0.05 to 0.35MPa, M: 0.3 to 1.0MPaThe set pressure adjustment range for nominal diameters 40 and 50 is 0.5 to 1.0 MPa, and the product symbols are WVM02-B (main unit FC) and WVM02-L (main unit FCD).
Nominal diameter 250 or more L: 0.05 to 0.35MPa, M: 0.3 to 0.7MPa
Blow-down pressure Set pressure adjustment range 0.05 to 0.35MPa: Set pressure x 20% or less (minimum value 0.03MPa)
Set pressure adjustment range 0.3 to 0.7, 0.3 to 1.0 MPa: Set pressure x 15% or less
Set pressure adjustment range 0.05 to 0.35MPa: Set pressure x 20% or less (minimum value 0.03MPa)
Set pressure adjustment range 0.3 to 0.7, 0.3 to 1.0 MPa: Set pressure x 15% or less
Accumulation Set pressure x 10% or less (minimum value 0.03MPa) Set pressure x 10% or less (minimum value 0.03MPa)
End connection JIS 10K RF flangeFor nominal diameters of 200 or less, we also manufacture primary side applicable pressure of 1.6MPa or less (JIS 16K RF flange, set pressure adjustment range of 0.5 to 1.6MPa). (If the main body is made of FC, it does not meet the performance standards of the Waterworks Law.) We also manufacture sluice valve flanges for waterworks (primary side applicable pressure 0.75 MPa or less, pressure resistance test 1.75 MPa, nominal diameter 80 or more). JIS 10K RF flangeFor nominal diameters of 200 or less, we also manufacture primary side applicable pressure of 1.6MPa or less (JIS 16K RF flange, set pressure adjustment range of 0.5 to 1.6MPa). (If the main body is made of FC, it does not meet the performance standards of the Waterworks Law.) We also manufacture sluice valve flanges for waterworks (primary side applicable pressure 0.75 MPa or less, pressure resistance test 1.75 MPa, nominal diameter 80 or more).
Pressure resistance test (water pressure) 1.5MPa 1.5MPa
Mounting posture Horizontal / verticalWhen installing in vertical piping, leave a large maintenance space. (However, if the nominal diameter is 250 or more, it is mounted upright on the horizontal pipe) Horizontal / verticalWhen installing in vertical piping, leave a large maintenance space. (However, if the nominal diameter is 250 or more, it is mounted upright on the horizontal pipe)
Basic valve material body FC FCD
Basic valve material Main part Diaphragm disc NBR NBR
Basic valve material Main part Valve seat CAC406 CAC406
Basic valve painting inner surface Liquid epoxy resin for water supply Liquid epoxy resin for water supply
Basic valve painting outer surface
  • We also manufacture WVM-02PN type (main body inner and outer surface epoxy resin powder coating) and WVM-02N type (main body inner surface water supply liquid epoxy resin coating) that conform to the performance standards of the Waterworks Law (main body material FC, nominal diameter 80-200). doing.
  • We also manufacture one with a pressure gauge. (The maximum scale of the pressure gauge is the set pressure adjustment range L (0.6MPa), M (1.6MPa).)
  • Please refer to page 157 of the general catalog for the nominal diameter selection chart and page 175 for the piping example diagram.

Download materials

Download materials

Common to all product symbols

WVM-02 Catalog

WVM-02 Price List

WVM-02(FCD_10K) outline drawing

WVM-02(FC_10K) outline drawing

WVM-02 (40,50A) Instruction Manual

WVM-02(65-200A) Instruction Manual

WVM02-B □

WVM02-B(50A) FC reference drawing

WVM02-B(65-200A) FC reference drawing

WVM02-L □

WVM02-L(40,50A) FCD reference drawing

Frequently Asked Questions and Explanations

What is the purpose of the primary pressure control valve installed on the outlet side of the pump?

It is used to prevent overheating due to shutoff operation of the pump and to keep the pump discharge pressure constant.

What is a back pressure valve?

Refers to the primary pressure control valve. A regulating valve that discharges fluid in response to changes in the force on the primary side in order to maintain the fluid pressure on the primary side at a certain constant pressure.

What is the purpose of the water fall prevention valve?

Please check the details.

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.