CB-M14B type
View favorites See the comparison
A control panel with a built-in seismic sensor and battery used for the emergency shutoff system of the water tank. A shutoff is output to the emergency shutoff valve when the seismic sensor is activated by an earthquake.
If the emergency shutoff valve is an electromagnetic type, it outputs a 24V DC shutoff valve closure. When the emergency shutoff valve is an electric type, it outputs a DC24V shutoff valve open signal except for the spring return type in normal times, but when the seismic sensor is operating, the polarity is switched and the shutoff valve is closed. ..
In addition, when the emergency shutoff valve is closed, the pump stop is also output, and the system status is always displayed as a lamp.
Where to use
For emergency shutoff system

Major features

  • We have a lineup of models that can control up to 2 or 4 emergency shutoff valves with one control panel.
  • The built-in battery maintains the emergency shutoff system for about 5 hours in the event of a power failure.

specification

Product code CBM14B-N
Valve type Electric type
Use For MR type
type control panel
Number of emergency shutoff valves 4 units
Power receiving power AC80-220V free power supply
Rated capacity 80VA
Protection class For both outdoor and indoor use (IP44)
Lightning strike measures Built-in surge absorption circuit in power supply
Backup power supply DC24V (sealed lead battery, 12V 2 pieces connected in series)The control output to the MRS type (spring return type) is AC100 or 200V, and the backup power supply is not built-in. The control panel model is CB-M □□ S type.
Backup time About 5 hours
Charging method (method) Always charging method (built-in trickle charging circuit)
Built-in battery CB-E12 type: PE12V 0.8Ah (replaced every 3 years)
CB-E14, M12A, M12B, M14A, M14B type: NP2.3-12 (replaced every 3 years)The control output to the MRS type (spring return type) is AC100 or 200V, and the backup power supply is not built-in. The control panel model is CB-M □□ S type.
Seismic device Operating acceleration: 200 gal (equivalent to seismic intensity 5+)
Output shutoff valve control output DC24VThe control output to the MRS type (spring return type) is AC100 or 200V, and the backup power supply is not built-in. The control panel model is CB-M □□ S type.
Output pump protection signal Non-voltage c contact output ………… 2 circuits
Output external alarm signal No voltage, ON contact when operating the seismic sensor
Output return switch Push button switch (for resetting the seismic sensor)
Display Power receiving display Green LED lamp display
Display Seismic device operation Orange LED lamp display
Display Shutoff valve open / close display Valve open display: 2 green LED lamps (2 units collectively displayed) Valve closed display: 2 red LED lamps (2 units collectively displayed)

Download materials

Download materials

Common to all product symbols

CB-M14B Catalog

CB-M14B price list

CB-M14B outline drawing

Frequently Asked Questions and Explanations

Is it possible to change the operating acceleration setting locally?

The operating acceleration cannot be changed in the field. Please contact us when ordering.

Is it possible to extract the operating signal?

EIM-2,3 Leeds is also manufactured with a limit switch (no voltage) as an option. The EIM-7 series has a limit switch (no voltage) on the closed side as standard.

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.