DS-11N type
View favorites See the comparison
The pressure at the pilot line of the constant water level valve drops extremely during water supply, and it may not be possible to operate with a pilot solenoid valve. Use the solenoid valve shown in the correspondence table for the constant water level valve.

specification

Product code DS11N-J □The rated voltage symbol is entered in □.
Valve type Solenoid valve for pilot
type Body made of bronze
Nominal diameter 15/20 (1/2/3/4)
Applicable pressure 0-0.75MPa
Rated voltage 1: AC100V 50 / 60Hz
2: AC200V 50 / 60Hz
Rated current AC100V: 0.19A AC200V: 0.10A
Starting current AC100V: 0.57A AC200V: 0.29A
Protective structure Dust-proof, drip-proof, for indoor useWhen using it outdoors, use the TB-03 series terminal box together.
Cv value 0.45
Material body CAC
Material parts SUS / FKM
  • The DS-11LN type also manufactures products with a built-in tube end core.

Download materials

Download materials

Common to all product symbols

DS-11N Catalog

DS-11N Price List

DS-11N outline drawing

DS-11N Instruction Manual

DS11N-J □

DS11N-J reference diagram

Frequently Asked Questions and Explanations

Is there any problem if the solenoid valve is used (energized) with the valve open for a long time?

The solenoid valve coil has a "continuous rating", so there is no problem even if it is used while it is energized.

The coil of the solenoid valve is hot, is that okay? (There is a video in the answer details)

There is no problem even if the coil part is hot. Please check the video explaining the answer in detail.

If the secondary side of the solenoid valve is a rising pipe, will there be a backflow? (Answer details include a reference video)

The solenoid valve has no inlet pressure, and if back pressure is applied, backflow will occur. In this case, install a check valve on the secondary side of the solenoid valve. (There is a reference video in the answer details.)

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.