WVL-02 type
View favorites See the comparison
A large-capacity constant water level valve used for water tanks, upland irrigation water tanks, decompression water tanks, etc.

specification

Product code WVL02-B WVL02-L
Valve type Constant water level valve Constant water level valve
type For general use For general use
Nominal diameter 80-400 (3-16) 80-200 (3-8)
Applicable fluid waterWhen using it for a water supply device, use WVL-02N type, WVL-02PN type, WVL-02CN type, which are compliant with the performance standards of the Waterworks Law. waterWhen using it for a water supply device, use WVL-02N type, WVL-02PN type, WVL-02CN type, which are compliant with the performance standards of the Waterworks Law.
Fluid temperature 5-60 ℃ 5-60 ℃
Applicable pressure Nominal diameter 200 or less: 0.03 to 0.75MPa, Nominal diameter 250 or more: 0.05 to 0.75MPa Nominal diameter 200 or less: 0.03 to 0.75MPa, Nominal diameter 250 or more: 0.05 to 0.75MPa
Minimum differential pressure before and after the valve Nominal diameter 200 or less: 0.03MPa, Nominal diameter 250 or more: 0.05MPa Nominal diameter 200 or less: 0.03MPa, Nominal diameter 250 or more: 0.05MPa
End connection JIS 10K RF flange or sluice valve flange for water supply JIS 10K RF flange or sluice valve flange for water supply
Mounting posture Upright mounting on horizontal piping Upright mounting on horizontal piping
Attached ball tap Body nominal diameter 200 or less: Nominal diameter 20 (with poly ball sand)The ball tap (LB-2N type, nominal diameter 20) is also sold separately. Please refer to page 188. Body nominal diameter 250 or more: Nominal diameter 25 (with poly ball sand) Body nominal diameter 200 or less: Nominal diameter 20 (with poly ball sand)The ball tap (LB-2N type, nominal diameter 20) is also sold separately. Please refer to page 188. Body nominal diameter 250 or more: Nominal diameter 25 (with poly ball sand)
Basic valve material body FC FCD
Basic valve material Main part Diaphragm disc Synthetic rubber Synthetic rubber
Basic valve material Main part Valve seat CAC406 CAC406
  • We also manufacture WVL-02PN type (main body inner and outer surface epoxy resin powder coating) and WVL-02N type (main body inner surface water supply liquid epoxy resin coating) that conform to the performance standards of the Waterworks Law (main body FC, nominal diameter 80-200). I have.
  • Please refer to page 157 for the nominal diameter selection chart.

Download materials

Download materials

Common to all product symbols

WVL-02 Catalog

WVL-02 Price List

WVL02-B

WVL02-B (manufactured by FC) reference drawing

WVL02-L

Frequently Asked Questions and Explanations

What kind of failure (complaint) does the constant water level valve have?

Please check the details.

Why do you use solenoid valves and ball taps together for pilot piping?

When using a solenoid valve, the water level is detected by the liquid level switch, and the main valve is opened and closed by the operation of the pilot solenoid valve to control the water level.

Is the flow rate adjustment mechanism of the constant water level valve a constant flow valve?

It is not a constant flow valve. The purpose is to regulate the maximum flow rate to prevent the water pressure drop in the water pipes during the daytime when tap water is in high demand.

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.