RP-8A type
View favorites See the comparison
A pilot type pressure reducing valve whose main body and main parts are made of stainless steel. In addition, it can be used in a wide range of applications due to the corrosion resistance and durability that are the characteristics of stainless steel.
Please refer to page 19 of the catalog for the nominal diameter selection chart.
Where to use
Factory equipmentVarious devices

Major features

  • Stable control is achieved by adopting a piston guide structure.
  • It can be used for a wide range of pressure and flow rates.
  • Pressure adjustment is easy due to the manual handle operation of the automatic lock mechanism.
  • It is a compact design.

specification

Product code RP8A-D
Nominal diameter 20-80 (3/4-3)
Applicable fluid Air / gas
Fluid temperature 5 ~ 80 ° C
Primary side applied pressure 1.0MPa or less
Secondary adjustment pressure range 0.03 ~ 0.8MPa
Maximum decompression ratio 10: 1
Minimum differential pressure before and after the valve 0.07MPa
Deadline boost 0.02MPa or less
offset Within 0.02MPa (Secondary adjustment pressure 0.03 to 0.035MPa) Within 0.03MPa (Secondary adjustment pressure over 0.035 0.07MPa) Within 0.05MPa (Secondary adjustment pressure over 0.07 0.8MPa)
Allowable leakage amount None (visual pressure gauge)
End connection JIS 10K FF flangeWe also manufacture JIS 10K RF flanges.
Material body SCS
Material Valve body SUS
Material Valve seat SUS
Material diaphragm SUS
Material disc NBR baking
Handle or cap color black
Mounting posture Upright mounting on horizontal piping
  • Use RD-20, 20F type for nominal diameter 15 and RP-11A type for nominal diameter 100 to 150.

Download materials

Download materials

Common to all product symbols

RP-8A Catalog

RP-8A price list

RP-8A outline drawing

RP-8A (15-80A) Instruction Manual

RP8A-D

RP8A-D reference diagram (nominal diameter 20, 25)

RP8A-D reference diagram (nominal diameter 32-80)

Frequently Asked Questions and Explanations

Is there a leak in the steam pressure reducing valve?

The allowable leakage amount is stated in the specifications of each product.

Does the fluid flow without pressure adjustment?

It doesn't flow. It will flow normally only after adjusting the pressure.

How should I perform maintenance and inspection of the steam pressure reducing valve?

We perform regular maintenance once a year as a guide. Please refer to the instruction manual for details.

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.