RC-47N type
View favorites See the comparison
The RD-47N type is a pressure reducing valve for water and hot water supply used in apartment buildings and high-rise buildings.
The RC-47N type is a pressure reducing valve that combines the RD-47N type with a check valve to prevent backflow from the equipment side to the main pipe side when water is cut off.
When using a pressure reducing valve for door-to-door water supply
1. 1. Running water noise is reduced.
2. Eliminates variations in water supply pressure due to height differences.
3. 3. Due to the proper pressure, the water splash phenomenon does not occur.
Four. During maintenance, the effect of water outage does not affect a wide area.
Five. The mixing temperature is stable.
Such as, living performance is improved.
Where to use
Large house

Major features

  • Uses chlorine water resistant EPDM.
  • Hygienic structure without liquid pool.
  • Reliable operation from low differential pressure to high differential pressure.
  • Easy and simple new test gag method adopted.
  • Even after construction, the water pressure test can be performed with the pressure reducing valve installed.
  • Maintenance is easy by adopting the cassette method.
  • With a structure without caulking or welding, all parts can be recycled and sorted.

Water Supply Law Performance Standard Certification Registered Product (E-551) Pressure Pressure Performance Leaching Performance Backflow Prevention Performance Durability Performance

specification

Product code RC47N-FLPL1 RC47N-FHPL6
Valve type Pressure reducing valve for door-to-door water supply Pressure reducing valve for door-to-door water supply
type Check valve for door-to-door water supply Check valve for door-to-door water supply
Nominal diameter 25 (1) 25 (1)
Applicable fluid Tap water / hot water Tap water / hot water
Fluid temperature 5 to 90 ° C (5 to 40 ° C when using tube end core) 5 to 90 ° C (5 to 40 ° C when using tube end core)
Primary side applied pressure 1.0MPa or less 1.0MPa or less
Secondary adjustment pressure range (set pressure) 0.05-0.13MPa (0.08MPa) 0.12 to 0.35MPa (0.2MPa)We also manufacture set pressures of 0.15 and 0.25 MPa. )
Nameplate color Green Red
Maximum decompression ratio 10: 1 10: 1
Minimum differential pressure before and after the valve 0.025MPa 0.025MPa
Rated flow rate 55L / min (differential pressure 0.1MPa or more) 65L / min (differential pressure 0.1MPa or more)
Check valve closing pressure 3kPa or more 3kPa or more
End connection JIS R1 (Union fitting) JIS R1 (Union fitting)
Mounting posture Horizontal / vertical freedom (excluding strainer cap upward) Horizontal / vertical freedom (excluding strainer cap upward)
accessories Union fittings (pipes, nuts, gaskets)In the case of RC-47N type, a check valve is built in the union joint on the outlet side. (It will be delivered as a set of the main body and union joint.) , Heat insulation case (self-extinguishing property), test gag, joint for pressure gauge (for secondary side, main body already attached)The pressure gauge fitting can be used in combination with the opposite plug. Union fittings (pipes, nuts, gaskets)In the case of RC-47N type, a check valve is built in the union joint on the outlet side. (It will be delivered as a set of the main body and union joint.) , Heat insulation case (self-extinguishing property), test gag, joint for pressure gauge (for secondary side, main body already attached)The pressure gauge fitting can be used in combination with the opposite plug.
strainer Equivalent to 40 mesh Equivalent to 40 mesh
Material body CAC911 CAC911
Material diaphragm Chlorine water resistant EPDM Chlorine water resistant EPDM
Material disc Chlorine water resistant EPDM Chlorine water resistant EPDM
  • The pressure gauge is an optional item, and A type or D type can be selected. (Refer to page 60 for the pressure gauge.)
  • For nominal diameter 20, use RD-44N, 44SN, 45SN type (see pages 52, 57, 58) or RC-44N, 45SUN type (see pages 54, 58).

Download materials

Download materials

Common to all product symbols

RC-47N Catalog

RC-47N price list

RC-47N outline drawing

RC-47N Instruction Manual

RC47N-FLPL1

RC-47N type L reference drawing

RC47N-FHPL6

RC-47N type H reference diagram

Frequently Asked Questions and Explanations

What is the useful life (the number of years recommended for replacement)?

The service life of pressure reducing valves for door-to-door water supply is 8 years after regular inspections, maintenance, and replacement of consumable parts, but this may vary depending on usage conditions.

Does the pressure reducing valve generate noise due to deterioration over time?

Noise tends to be higher due to disc damage (bite) and benza damage over time.

Is it necessary to install a pressure reducing valve for water supply for each house in all the units of an apartment house?

Not all units have it. It is not necessary to install it if the water pressure is not high on the upper floors.

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.