SL-46ED type
View favorites See the comparison
SL-46ED, 6ED type pump relief valve is a relief valve for pressure adjustment exclusively for pumps. Stable pressure due to damper mechanism
Since it can perform detection, it can also be applied to volumetric pumps such as plunger pumps. In addition, because of the back pressure balance structure, it is not affected by back pressure and is ideal for thermal relief.
Where to use
For pump onlyFor thermal relief

Major features

  • The damper mechanism of the valve body suppresses the sudden movement of the valve body due to pulsating pressure and fluctuating pressure at high pressure.
  • It is a back pressure balance structure that eliminates the influence of back pressure due to the piping condition on the relief valve outlet side.

specification

Product code SL46ED-M □The pressure classification symbol is entered in □.
format Relief valve
Cap format No lever
Nominal diameter 40-75 (1 1/2-3)
Applicable fluid Water / oil / liquid
Set pressure range 0.035-2.0MPa
Fluid temperature Manufactured up to 5-80 ° C (up to 150 ° C).Oils are below 150 ℃, and hot water is below 90 ℃. )
Maximum allowable back pressure 1.0MPa
End connection JIS 20K FF flangeWe also manufacture JIS 10, 16K FF / RF flanges and JIS 20K RF flanges.
Mounting posture Upright mounting
Material body FCD
Material parts SUS

Download materials

Download materials

Common to all product symbols

SL-46ED Catalog

SL-46ED price list

SL-46ED Instruction Manual

SL46ED-M □

SL46ED-M reference diagram (nominal diameter 40-75)

Frequently Asked Questions and Explanations

Please tell me the difference between the head type and the full volume type. (Answer details include a video)

There is a difference in the amount of blowout between the lift type and the total amount type. Either one can be used as long as the required amount of blowout is satisfied.

What is the purpose of the safety valve lever? (There is a video in the answer details)

This is to check if the safety valve can be operated and if there is any abnormality (sticking). (Operate when the pressure on the inlet side is 75% or more of the set pressure.)

Please tell me how to select the safety valve with lever and without lever.

As a general rule, select no lever (sealed type) for fluids that adversely affect the surroundings when the safety valve operates, such as flammable / toxic and liquid. If it is necessary to check the operation of the safety valve by operating the lever, select the one with a lever.

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by phone, please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

How easy was it to find the page you were looking for on this site?

How was the page easy to understand about this site?

Thank you for your cooperation

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

No hits in product search
RP7-FL
Hit in product search
RP7-FL
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.